전체상품목록 바로가기

본문 바로가기


현재 위치
  1. 제품
공급사 바로가기

PS251

(해외배송 가능상품)
기본 정보
상품명 PS251
상품간략설명

Manual
판매가 문의
상품요약정보 25MHz, 2CH Analog Oscilloscope
제조사 PINTEK
수량 수량증가수량감소
옵션바로선택

개인결제창을 통한 결제 시 네이버 마일리지 적립 및 사용이 가능합니다.

상품 옵션
옵션 선택

(최소주문수량 1개 이상 / 최대주문수량 0개 이하)

사이즈 가이드
상품 목록
상품명 상품수 가격
PS251 수량증가 수량감소 문의 (  )
총 상품금액(수량) : 0 (0개)

이벤트


특    징


25MHz, 2ch, ALT Trigger
 1mV sensitivity.
 10ns Resolution.
 Component test, Beam-finder
 Illuminate, Hold-off, X-Y




사    양


CRT

Type : Rectangular with integral grateful.
Display Area : 8 x 10 div (1 div= 1 cm)
Accelerating Voltage : 2.1 kV.
Phosphor : P31

수직축(Vertical) (CH 1 and CH 2)
Sensitivity : 5 mV/div to 5V/div (X1 mode).
1 mV/div to 1V/div (X5 mode). 1-2-5 sequence, 10 step attenuator.
Accuracy : ±3% (X1 mode). ±5% (X5 mode).
Input Resistance : 1 M±2%
Input Capacitance : 25 pF//10pF.
Rise Time : Approximately 14.0ns.
Operating Modes : CH1 : CH 1, single trace. CH2 : CH 2,
single trace. ALT : dual trace, alternating.
CHOP : dual trace, chopped. ADD : sum of CH 1 + CH 2
Polarity Reversal (Invert) : CH 2 only.
Maximum Input Voltage : 400 V dv + ac peak
Maximum Undistorted Amplitude : DC-to-25 MHz : 4 divisions. DC-to-15 MHz : 8 divisions.

HORIZONTAL(수평축) (Input through channel 1 input)
X-Y mode : switch selectable using X-Y switch.
CH 1 : X axis CH 2 : Y axis
Sensitivity : 1mv/div to 5v/div
Accuracy : Y-Axis : ±3% ±X-Axis : ±6%
Input Impedance : 1M//25PF
Frequency Response : DC to 1 MHz typical (-3 dB)
X-Y Phase Difference : Approximately 3o at 50 kHz.
Maximum input Voltage : 400Vdc+ac peak

SWEEP SYSTEM
Sweep Speed : 0.1 μs/div to 2 s/div in 1-2-5 sequence, 23 steps.
Vernier control provides fully
Accuracy : ±3%
Sweep Magnification : 10X, ±6% (0.1 μs and 0.2 μs ranges uncaliubrated when X10 is engaged).
Holdoff : Continuously adjustable from NORM to 5 times normal.

TRIGGERING
Trigger Source : CH 1, CH 2, ALT, EXT, LINE.
Maximum External Trigger Voltage : 300V dc + ac peak.
Trigger Coupling : AC : 30 Hz to 30 MHz TV - H : Used for triggering from horizontal sync pulses.
TV - V : Used for triggering from vertical sync pulses.
Trigger Sensitivity : Internal : 0.5 division (1 division with TV Coupling) External : 500 mV

COMPONENT TEST
Test Voltage : Max. 6 Vrms (open circuit).
Test Current : Max. 11 mA(shorted).
Test Frequency : Line Frequency
Components : Capacitor, Inductor, Diode, Transistor, Zener etc.

OTHER SPECIFICATIONS
BEAM FINDER : Trace can be return to CRT center area when press beam finder button.
GRATICULE ILLUMINATION : Adjustable
Calibration Voltage : 1 kHz (nominal) Positive Square Wave, 2.0 V p-p (±3%)
Trace Rotation : Electrical, front panel adjustable.
Power Requirements : 115/230 VAC ±10%, 50/60Hz
Dimensions : 324 x 132 x 398 mm (12.8 x 5.2 x 15.6").
Weight : Approximately 7.6kg (16.75bs).

Standard Accessories : Power cord x 1, Operating manual x 1, Probe x 2


WORLD SHIPPING

PLEASE SELECT THE DESTINATION COUNTRY AND LANGUAGE :

GO
close
카카오톡
네이버톡톡
PSYS
Blog

TODAY'S
ITEMS

  • 버튼
  • 버튼
 

QUICK ICONS

라인

  • 공지사항
  • 문의하기
  • 카탈로그