사 양
Model | DG1022 |
Max. Output Frequency | 20MHz (5MHz square wave) |
Output Channels | 2 |
Sample Rate | 100MS/s |
Arbitrary Waveform Length | CH1 : 2pts ~ 4kpts CH2 : 2pts ~ 1kpts |
Resolution | 1uHz |
Amplitude | CH1 : 2mVpp ~ 10Vpp(50Ω), 4mVpp ~ 20Vpp(High Z) CH2 : 2mVpp ~ 3Vpp(50Ω), 4mVpp ~ 6Vpp(High Z) |
Vertical Resolution | CH1 : 14 bits CH2 : 10 bits |
Standard Interface | USB Host & Device |
표준부속품
▶ A Power Cord that fits the standard of destination country
▶ A Quick Guide
▶ A BNC Cable
Options
▶ BNC to Alligator Clip Cable
▶ USB Cable
▶ RA5040K : 40dB Attenuator
▶ PA1011 : 10W Power Amplifier
F A Q
C#.Net DG1022 example program: Load and run an Arbitrary Waveform This example shows how to program a user defined arbitrary waveform into a DG1022 using C#.NET and VISA.
How do I load an arbitrary waveform into my DG1022? Here are instructions on loading arbitrary waveforms using the front panel of the DG1000 series of Arbitrary waveform generators.
LabVIEW 2011 General Example for the DG1000 Series of Arbitrary Waveform Generators. This code allows users to select the function, amplitude, and frequency of a waveform and download it to a DG1000 series of arbitrary waveform generator. Users can also enable and disable the outputs remotely.
Can the DG1022 Channel 2 be used in Modulation, Sweep, or Burst mode? No. The DG1022 Channel 2 has limited functionality. Please refer to the User's Manual for more information.
DG1000 Packing list The attachment contains a packing list for the items included in the DG1022 and DG1022A products.
DG1000 Calibration Certificate Here is an example of a calibration certificate for the DG1022 and DG1022A family of Arbitrary Waveform Generators.
How do I select and stored arbitrary waveform on a DG1022? Here are simple instructions to load an Arbitrary Waveform: 1. Press "ARB" function key on the front panel of the instrument. 2. Press the blue-grey "Load" softkey. 3. Press the blue-grey "Stored" softkey. 4. Use scroll wheel to select the ARB of interest.. the selected
How do I find the serial number and firmware revision of my DG1022? Follow the attached PDF instructions to determine the revision information for your Arbitrary Waveform generator.
How to add noise to a waveform using UltraWave. Here are step-by-step instructions that will help you add noise to a waveform using Rigol's UltraWave software.
How do I use an external 10MHz clock on the DG1000 Series?
Press Utility > Right Arrow > System > Setting > Timer
DG1022 Quick Guide
How to build multisegment waveforms with UltraWave UltraWave is a waveform editing software tool for use with the Rigol DG1022/A, DG2041A, and DG3 arbitrary waveform generators. This note shows an example of using UltraWave to create a multisegment waveform.
Where do I find instrument drivers for LabVIEW?
When I plug in my instrument via USB, I get a Windows Page Fault error ( Blue Screen of Death / BSoD ). There is a known issue with the IVI VISA Shared components version. See attached document for more details.
Why does the amplitude of my function generator not match the displayed amplitude? Instruments like the Rigol DG Arbitrary Waveform Generators are designed with a 50 ohm output impedance in parallel with the output of the instrument. When a circuit or device is connected to the output, it is electrically connected in parallel to this 50 ohms. With such
Software Compatibility The attached PDF file describes Windows 7 Compatibility Issues.
VISA Runtime for Apple OS X To use a VISA compatible Rigol instrument under Apple OS X, the user must install National Instruments VISA run-time engine for OS X As of this writing the latest OS X VISA run-time engine from National Instruments is NI-VISA 5.0 NI-VISA 5.0 can be downloaded directly
Help File Error: Navigation to web page cancelled. Some instrument manuals are compiled HTML files with extensions ending in .CHM. On occasion, they have shown "Navigation to web page cancelled". Here are some steps to help solve that error.
Bits vs. dBs Here are instructions on converting bits of resolution to dBs.
My Instrument IVI Driver does not appear in the LabVIEW tools palette. You may need to manually find and convert the IVI driver. See attachment for more details.
The instrument not recognized over the USB bus In some cases, an instrument may not be recognized over the USB bus. Here are some troubleshooting hints to help.
Are your products UL or CSA listed?
Rigol Scopes VISA Driver Installation / Rigol's UltraScope software not detect Rigol scope attached to PC via USB OR User receives "Run Time Error '48': File not found VISA32.DLL" error message when UltraScope is launched. The user either has not installed the latest available National Instruments VISA Runtime engine or the version of National Instrument’s VISA Runtime Engine included on the CD that the user installed is outdated. In both cases, the recommended solution is to visit National
How do I phase synchronize two arbitrary waveform generators? Here are brief instructions on synchronizing the phase of two waveform generators.
Does the instrument clock accuracy match the external clock accuracy?
VB.NET basic instrument communication example Here is a short example on using National Instrument VISA and VB.NET to communicate with an instrument.
How to use Burst mode to precisely synchronize the outputs of multiple generators. Many arbitrary waveform generators have burst mode. This can be used to tightly synchronize the outputs of multiple generators.
Basic phase alignment of two output signals with the DG series This note shows the basic technique of aligning two phases on a dual channel DG series arbitrary waveform generator.
What is the file format used with DG arbitrary waveforms? The attached document highlights the file formats used in the DG1000, DG1000Z, DG4000, and DG5000 series of arbitrary waveform generators.
PyVISA example of instrument control via Python and NI-VISA A short example showing instrument communications using the PyVISA 1.4 VISA wrapper with Python 2.7.9 and National Instruments VISA layer.
NationalInstruments.Common and NationalInstruments.VisaNS are not being found with .NET
Go to Solution Explorer, right click on the file of interest (NationalInstruments.Common or NationalInstruments.VisaNS) and change Specific Version to False.
Firmware update troubleshooting Tips Here are some tips if you are having issues updating the firmware on a Rigol product.
Why does the amplitude drop to 0V for a time when I change the duty cycle on my DG1022 or DG4000? The DG1022 and DG4000 arbitrary waveform generators have a hardware limitation that prevents them from output during a duty cycle change. During the transition from one duty cycle value to another, the amplitude will be at 0V. If your application requires a smooth transition
Application Note
SiFi Technology in Arb Wave Creation Application note outlining the advantages of SiFI technology vs. DDS technology in making and using arbitrary waves.
What are the number of points captured by a DS1000E/D and replayed on a DG1022? The attached FAQ describes how waveform files (WFM file extensions) are mapped to the DG1022 arbitrary waveform mode.
DSG Signal Emulation App Note Application details on using a DSG800 series Signal Source to emulate and debug 2.4 GHz RF systems
Precompliance: Susceptibility testing This Application note covers tips and tricks to performing precompliance susceptibility testing.
PA1011 Power Amplifier Application Note
FM signal transmission and demodulation demo This application uses a DG4162 arbitrary waveform generator and audio source to create a custom FM transmission and then a DSA-1030A spectrum analyzer to receive and demodulate the signal.