▶QPSK 및 QAM 형식을 포함하는 디지털 베이스 밴드 생성을 위한 IQ 변조를 포함하여 표준 변조 내장
▶ Output Amplifier(PA-1011), Frequency hopping 기능 지원 가능(옵션)
▶GPIB(기본장착)
화 면
4.3 inches, 16M true color TFT LCD. Intuitive Front Panel and GUI
샘플링율 1GSa/s, 14bits, 1CH 혹은 2CH
다양한 sweep 타입
Whole range of Analog/Digital modulation functions
IQ 변조
IQ 맵핑 선택
주파수홉핑
Interface : USB Host& Device, LAN(LXI-C), GPIB
사 양
Model
DG5071 / DG5101/ DG5251 / DG5351
DG5072 / DG5102 / DG5252 / DG5352
Channels
1
2
Sample Rate
1GS/s
Waveform Length
Up to 128Mpts
Resolution
1uHz
Amplitude range
5mVpp ~ 10Vpp(50Ω), 10mVpp ~ 20Vpp(into open circuit)
Vertical Resolution
14 bits
Standard Interface
USB Host(2), USB Device, GPIB, LXI-C(Ethernet)
Options
Hop Frequency Module, Logic Signal Output Module, Power Amplifier
Weight
Approx. 4.5kg
표준부속품
▶Power Cord
▶BNC Cable (1 meter)
▶Quick Guide (Hard Copy)
▶SMB(F) to BNC(M) Cable (1 meter)
Options
▶FH-DG5000 : Frequency Hopping
▶DG POD : 16ch logic output module
▶Ultra-station-ADV : Ultra station Advanced Function
▶RA5040K : 40dB Attenuator
▶PA1011 : 10W Power Amplifier
▶USB Cable
동영상
F A Q
More information about Pulse Width Modulation (PWM)
This note describes PWM schemes in more detail. We also cover configuring a DG4000 for PWM output and a short description of the current pulse and PWM capabilities of our product line.
How to activate the frequency hopping option of DG5000 series?
This solution outlines the upgrade procedure for the frequency hopping option available on the DG5000 series of arbitrary waveform generators.
DG5000 Packing List
Attached is an example of the packing list of all included items in the DG5000 series.
What products are LXI compliant?
The attached document lists the LXI Compliant instruments.
DG5000 Self Test Procedure
How to perform a self test and clear the FRAM fail indication. This "false" fail will appear after power cycle and can only be cleared using this procedure every time.
DG5000 IVI Driver Example LabVIEW 2011
Here is a basic control program using the DG5000 IVI Driver written in LabVIEW 2011.
What are the remote programming commands to build an Arb using ASCII with a DG5000?
Here is an example showing the command order and structure to remotely program a DG5000 Arbitrary Waveform Generator with ASCII values.
What is the channel-to-channel isolation for dual channel DG5000 Arbitrary Waveform Generator?
2MOhms.
Using CSV files with UltraStation
This note describes how to cut-and-paste CSV data to a CSV template and download the waveform to an arbitrary waveform generator. It also contains CSV templates for the DG1Z, DG4, and DG5 series of arbitrary waveform generators.
How to burst a modulated waveform with a DG
LAN Troubleshooting using PuTTY
PuTTY is an open source network terminal emulator. It can be easily configured to help troubleshoot LAN connection issues to instrumentation.
DG5000 Quick Guide
Request the Latest Firmware
Click here and input information and we will get back to you with information on new firmware features and options available.
When I plug in my instrument via USB, I get a Windows Page Fault error ( Blue Screen of Death / BSoD ).
There is a known issue with the IVI VISA Shared components version. See attached document for more details.
Why does the amplitude of my function generator not match the displayed amplitude?
Instruments like the Rigol DG Arbitrary Waveform Generators are designed with a 50 ohm output impedance in parallel with the output of the instrument. When a circuit or device is connected to the output, it is electrically connected in parallel to this 50 ohms. With such
Software Compatibility
The attached PDF file describes Windows 7 Compatibility Issues.
VISA Runtime for Apple OS X
To use a VISA compatible Rigol instrument under Apple OS X, the user must install National Instruments VISA run-time engine for OS X As of this writing the latest OS X VISA run-time engine from National Instruments is NI-VISA 5.0 NI-VISA 5.0 can be downloaded directly
Help File Error: Navigation to web page cancelled.
Some instrument manuals are compiled HTML files with extensions ending in .CHM. On occasion, they have shown "Navigation to web page cancelled". Here are some steps to help solve that error.
Bits vs. dBs
Here are instructions on converting bits of resolution to dBs.
My Instrument IVI Driver does not appear in the LabVIEW tools palette.
You may need to manually find and convert the IVI driver. See attachment for more details.
The instrument not recognized over the USB bus
In some cases, an instrument may not be recognized over the USB bus. Here are some troubleshooting hints to help.
Are your products UL or CSA listed?
At this time, many of our products are C TUV USA listed. Per the TUV website,http://www.certipedia.com/companies/37679/certificates?locale=enThe C TUV US mark is recognized as the equivalent and direct replacement to the UL and CSA marks by city, county and state/provincial
Rigol Scopes VISA Driver Installation / Rigol's UltraScope software not detect Rigol scope attached to PC via USB OR User receives "Run Time Error '48': File not found VISA32.DLL" error message when UltraScope is launched.
The user either has not installed the latest available National Instruments VISA Runtime engine or the version of National Instrument’s VISA Runtime Engine included on the CD that the user installed is outdated. In both cases, the recommended solution is to visit National
How do I phase synchronize two arbitrary waveform generators?
Here are brief instructions on synchronizing the phase of two waveform generators.
Does the instrument clock accuracy match the external clock accuracy?
VB.NET basic instrument communication example
Here is a short example on using National Instrument VISA and VB.NET to communicate with an instrument.
How to use Burst mode to precisely synchronize the outputs of multiple generators.
Many arbitrary waveform generators have burst mode. This can be used to tightly synchronize the outputs of multiple generators.
Basic phase alignment of two output signals with the DG series
This note shows the basic technique of aligning two phases on a dual channel DG series arbitrary waveform generator.
What is the file format used with DG arbitrary waveforms?
The attached document highlights the file formats used in the DG1000, DG1000Z, DG4000, and DG5000 series of arbitrary waveform generators.
PyVISA example of instrument control via Python and NI-VISA
A short example showing instrument communications using the PyVISA 1.4 VISA wrapper with Python 2.7.9 and National Instruments VISA layer.
NationalInstruments.Common and NationalInstruments.VisaNS are not being found with .NET
Go to Solution Explorer, right click on the file of interest (NationalInstruments.Common or NationalInstruments.VisaNS) and change Specific Version to False.
Firmware update troubleshooting Tips
Here are some tips if you are having issues updating the firmware on a Rigol product.
Why does the amplitude drop to 0V for a time when I change the duty cycle on my DG1022 or DG4000?
The DG1022 and DG4000 arbitrary waveform generators have a hardware limitation that prevents them from output during a duty cycle change. During the transition from one duty cycle value to another, the amplitude will be at 0V. If your application requires a smooth transition
Application Note
Synchronizing Multiple DG5000s
This application note describes synchronizing four output signals from 2 DG5000 Aribitrary Waveform Generators.
DSG Signal Emulation App Note
Application details on using a DSG800 series Signal Source to emulate and debug 2.4 GHz RF systems
Precompliance: Susceptibility testing
This Application note covers tips and tricks to performing precompliance susceptibility testing.
PA1011 Power Amplifier Application Note
FM signal transmission and demodulation demo
This application uses a DG4162 arbitrary waveform generator and audio source to create a custom FM transmission and then a DSA-1030A spectrum analyzer to receive and demodulate the signal.