▶트리거 모드 Edge, Pulse width, Slope, Video, RS-232, I2C, SPI, CAN 지원
▶USB/LAN interface, VGA, AUX,GPIB(Option : USB to GPIB Adaptor)
Ultravision platform
화 면
대용량 메모리(표준 140Mpts)
최대 파형포착속도 180kwfms/s
실시간 파형기록, 재생, 분석
Serial bus 트리거 및 디코딩
Mask (Pass/Fail)기능
사 양
Model
DS6062 / DS6064 / DS6102 / DS6104
Bandwidth
600 MHz / 1GHz
Analog Channels
2 / 4
Vertical Sensitivity
2mV/div ~ 10V/div
Real-time Sample Rate
5GS/s
Memory Depth
140Mpts
Waveform Acquisition Rate
180,000wfms/s
Standard Interface
USB Host & Device, VGA, LXI, Trigger Out, 10MHz IN/OUT
Vertical Resolution
8 bits
Math
+, -, x, FFT, customizable user defined
Cursor Measurements
Manual, Track, Auto Measure modes
표준부속품
▶Power Cord conforming to the standard of the country
▶600MHz BW Passive Probe,4 sets for 4 channel models, 2 sets for 2 channel models
▶1.5GHz BW Passive Probe,2 sets for DS6104,1 set for DS6102
▶Quick Guide
Options
▶ARM : Desk mount unstrument Arm
▶SD-RS232-DS6k : RS232/UART decording kit
▶SD-I2C/SPI-DS6k : I2C/SPI decording kit
▶SD-CAN-DS6k : CAN decording kit
▶SD-Flexray-DS6k : Flexray decording kit
▶ 1.5 GHz Active Differential Probe
▶ 500 MHz BW Passive Probes
▶ 600 MHz BW Passive Probe
▶ 1.5 GHz BW Passive Probe
▶ USB-GPIB : USB to GPIB Module
▶FPCS-DS6000 : Front cover
▶USB Data Cable
동영상
F A Q
DS610x Packing list
Here is a sample of the DS610x Series of 1GHz Oscilloscope packing list.
Can you disable the AUTOSET button on the DS4 and DS6 series?
Not at this time.
How do I check the trigger rate of a DS6 or DS4 series of oscilloscope?
You can use any unused channel on the DS4 or DS6 scope as a counter. Simply connect a BNC cable from the Trigger out connection on the back of the scope to the unused channel. Configure the Trigger connector as a Trigger Output and the unused channel as a counter. The
What products are LXI compliant?
The attached document lists the LXI Compliant instruments.
Enabling Maximum Recording Length
The DS2, 4, and 6000 series of oscilloscopes feature powerful record, playback, and analyze capabilities. Here are simple instructions on how to enable the maximum number of available frames for your scope.
PCK-100 Users Guide
Here are the calibration instructions for use with the PCK-100 Kit.
Maximum Acquisition times for DS2000 DS4000 DS6000 scopes
Here are timing charts showing maximum acquisition times for some of our deep memory scopes.
DS6000 and DS4000 (Version before 00.01.00.00.06) WFM converter
Here is a small application that will convert waveform files (extension *.WFM) to CSV text files.
DS2000 DS4000 DS6000 Firmware Upgrade Procedure
Here are the instructions for upgrading the firmware on your DS2, 4, or 6000 series of scopes.
Zoom and Pan through a waveform with Ultravision.
Here are some helpful steps to using the Zoom and Pan features of the DS2000, DS4000, and DS6000 Scopes.
Request the Latest Firmware
Click here and input information and we will get back to you with information on new firmware features and options available.
How to invert and change the background color on the DS2000/A, DS4000, and DS6000 scopes
You can change the color and invert the color palette used to save displayed images. This can save on ink by changing the background and trace color of saved images.
Option license activation process for the DS1000Z, DS2000/A, DS4000, and DS6000 Oscilloscopes
Here are instructions for activating licenses for the DS1000Z, DS2000/A, DS4000, and DS6000 series of oscilloscopes.
Here are brief instructions on returning the oscilloscope to factory defaults.
Screen capture example VI
This is a LabVIEW example that demonstrates retrieval of a screen capture from a Rigol DS series scope.
DS1000Z Deep Memory Data Collection Example
UltraVision scope deep memory collection information
How to find the expanded hardware revision of a DS1000Z, DS2000A, DS4000, and DS6000 scope
Print a picture/display using the STORAGE menu and enable parameters. This will save off a text file of the scope details. You can also enter Project Mode and then check the system. - Set the trigger type to Edge - Press the bottom/right grey/blue softkey next to the display
RP7000 Users Guide
Square wave displayed as sine wave on an oscilloscope.
A scope user attempting to view a square wave on an oscilloscope might view a sine wave of the same frequency in place of a square wave. This is not a necessarily a sign of a defect with the scope or the generator, however an effect of the constituent higher frequency harmonic
How do I configure a DS1000B Series Oscilloscope to return maximum data lengths?
This note covers how to configure the DS1000B series of oscilloscope to return the maximum data length. This can be useful for storing to a USB memory stick.
Can you set up any RIGOL scopes to stop triggering after a specific averaging number?
Not at this time. The average acquisition mode for the DS1000E/D, DS1000CA, DS1000B, DS4000, and DS6000 scopes are identical in function. They collect a boxcar average of the last acquisitions on a rolling basis.
When I plug in my instrument via USB, I get a Windows Page Fault error ( Blue Screen of Death / BSoD ).
There is a known issue with the IVI VISA Shared components version. See attached document for more details.
Software Compatibility
The attached PDF file describes Windows 7 Compatibility Issues.
VISA Runtime for Apple OS X
To use a VISA compatible Rigol instrument under Apple OS X, the user must install National Instruments VISA run-time engine for OS X As of this writing the latest OS X VISA run-time engine from National Instruments is NI-VISA 5.0 NI-VISA 5.0 can be downloaded directly
What is the capacitance of the RP6150 and RP6150A passive probe?
1.6pF.
Help File Error: Navigation to web page cancelled.
Some instrument manuals are compiled HTML files with extensions ending in .CHM. On occasion, they have shown "Navigation to web page cancelled". Here are some steps to help solve that error.
RP1300H Users Guide
RP2200 Users Guide
RP1050H Users Guide
RP5600 Users Guide
RP6150 Users Guide
Standard probes for all scopes
Here is a listing of the standard probes that ship with each scope.
Why does my data not appear to have 8 bits of resolution?
The displayed data is a subset of the actual total measurement range. This is mainly due to a smaller number of vertical pixels than bits available. See attached for more details.
Benefits of deep memory
Modern oscilloscopes feature many powerful tools to help you get your job done. Here are some of the benefits of deep memory.
Bits vs. dBs
Here are instructions on converting bits of resolution to dBs.
My Instrument IVI Driver does not appear in the LabVIEW tools palette.
You may need to manually find and convert the IVI driver. See attachment for more details.
The instrument not recognized over the USB bus
In some cases, an instrument may not be recognized over the USB bus. Here are some troubleshooting hints to help.
Are your products UL or CSA listed?
At this time, many of our products are C TUV USA listed. Per the TUV website,http://www.certipedia.com/companies/37679/certificates?locale=enThe C TUV US mark is recognized as the equivalent and direct replacement to the UL and CSA marks by city, county and state/provincial
Rigol Scopes VISA Driver Installation / Rigol's UltraScope software not detect Rigol scope attached to PC via USB OR User receives "Run Time Error '48': File not found VISA32.DLL" error message when UltraScope is launched.
The user either has not installed the latest available National Instruments VISA Runtime engine or the version of National Instrument’s VISA Runtime Engine included on the CD that the user installed is outdated. In both cases, the recommended solution is to visit National
RP3300A Users Guide
VB.NET basic instrument communication example
Here is a short example on using National Instrument VISA and VB.NET to communicate with an instrument.
PyVISA example of instrument control via Python and NI-VISA
A short example showing instrument communications using the PyVISA 1.4 VISA wrapper with Python 2.7.9 and National Instruments VISA layer.
Why does my DS series trigger rate slow down with failed waveforms in Pass/Fail mode?
When a waveform fails the pass/fail mask test, the trigger hold off is intentionally increased to give the observer time to see the failed waveform.
LAN Troubleshooting using PuTTY
PuTTY is an open source network terminal emulator. It can be easily configured to help troubleshoot LAN connection issues to instrumentation.
NationalInstruments.Common and NationalInstruments.VisaNS are not being found with .NET
Go to Solution Explorer, right click on the file of interest (NationalInstruments.Common or NationalInstruments.VisaNS) and change Specific Version to False.
What data set size is used to calculate the FFT on the DS series of scopes?
The FFT is calculated using the displayed data set. DS1000E/D/B/CA series scopes = 600 Data points DS1000Z Series (Displayed) = 1200 (Memory) = 16,384 DS2000 Series = 2048 points DS4000 series = 2048 points DS6000 series = 2048 points
Why do digital scopes appear noisy?
Dave Jones, of EEVBlog, explains why digital scopes appear noisier than their Analog counterparts.
Firmware update troubleshooting Tips
Here are some tips if you are having issues updating the firmware on a Rigol product.
Direct waveform transfer from a DS scope to a DG4000 generator
You can directly transfer any waveform captured on a DS series scope to a DG4000 generator using a USB cable and a few easy steps. See attached for more details.
Application Note
DS6000 Video Signal and Glitch Demonstration Note
Advantage of Record function
This App-Note explains the advantage and the usage of the Rigol Record Funktion. Also shown: Serial Bus Decoding + Record Function = great tool for debugging and error search on busses.
Why can't I get a DSA battery and is there a workaround for portable use?
We are unable to import the Li-Ion batteries at this time. We recommend using a true sine wave inverter for portable use. See attached for performance data for a DSA800 while running on battery.